Special Features
  • High accuracy and better lifetime achieved using photo Ionization Detection(PID) sensor Technology
  • Optimized for detection of smallest leak of VOCs (IP<10.6eV)
  • Highly resistant to poisoning and etching
  • Capable of detecting down to PPB to PPM
  • Auto ranging of Gas concentration from PPB to PPM
  • Digital Alphanumeric display with configurable backlit option.
  • Standard 4-20mA Signal output with configurable range.
  • Easy handling and programming with 3 keys for WP Mode’.
  • Can be programmed using Remote Control upto 10 meters line of site distance.
  • Non Intrusive programming for Flameproof model using Magnetic pen
  • Password protected programming menu.
  • One man Auto software Gas calibration.
  • Optional Alarm relay contacts with two configurabie Alarm levels.
  • Optional STEL and TWA set points can be configured for all VOCs In PPM level.
  • Optional RS-485 communication port with MODBUS RTU Protocol
Technical Information
DETECTION METHOD Photo Ionization Detection
GASES DETECTION Volatile Organic Compounds Ionization Potential Less than 10.6eV().Select from table below
DISPLAY 8 x 2 Alphanumeric LCD with configurable Backlit option
CONTROL ACTION i) Two independent alarm set points with Latch & Non-Latch facility.
ii) User selectable Hysteresis and logic option
iii) Configurable STEL and TWA set points for all VOCs (optional) in PPM Level.
SETTING By using 3 keys on front panel for WP/FLP Model.
By using Magnetic pen for FLP model
By using Remote control for WP/FLP Model (Optional)
OUTPUT 4-20 mA
AUTO-RANGING From PPB to PPM
PERFORMANCE
ACCURACY ± 2% of F.S
RESPONSE TIME T20 < 1 Second
T50 < 4 Seconds
T90 < 8 Seconds
START-UP TIME Less than 30 secs
ELECTRICAL
SUPPLY VOLTAGE 18 t0 36 VDC, Typically 24 VDC
POWER CONSUMPTION Less than 3.5 Watts
CABLE 3 Wire (1.52) Flexible or Armoured Shielded
WEATHERPROOF HOUSING
PROTECTION LASS IP – 65
OUTPUT SIGNAL
STANDARD 4-20mA Current Output with configurable range selection
OPTIONAL Two SPDT Relays of rating "120VAC/2A, 24VDC/24".
Optional RS-485 Communication port with MODBUS RTU protocol
ERROR MONITORING
SENSOR BREAK / OPEN The display shows 'SENSOR OPEN' & 4-20mA output goes down to 3.7 mA
OVER RANGE The display shows 'OVER RANGE' & 4-20mA output goes up to 21 mA
ENVIRONMENT
OPERATING TEMPERATURE -30 to +50C ±5%
STORAGE TEMPERATURE -40 to +60C ±5%
HUMIDITY 95% Non-Condensing
ACCESSORIES
CERTIFIED 24 VDC POWER SUPPLY RS-232 to RS-485 convertor Hooter Cum Flasher
CANOPY MOUNTING STAND Gas Calibration Kit
SCADA SOFTWARE Remote Control
RS-485 TO USB CONVERTOR Sampling System
FLAMEPROOF HOUSING
PROTECTION CLASS IP-65 for Gas Gr.II,IIB & CMRI approved enclosure, CCOE (Optional)
CABINET MATERIAL Cast Aluminium alloy, LM-6
CABLE ENTRY Double Compression cable gland (Ex-Proof),
3/4th ET- type
DIMENSION 180 mm (H) x 242 mm (W) x 126 mm (D)
MOUNTING Wall mounting / Stand Mounting / Pipe Mounting
WEIGHT Approx. 2.0 kg